Skip to main content

Troubleshooting

First check what the price checker screen shows, then open the settings and press Connection test on the Source tab — the test gives a more detailed message than the customer screen.

Messages on the price checker screen​

MessageWhat it meansWhat to do
Scan the codeThe app is ready.–
LoadingThe app is connecting to the source or waiting for the response after a scan.If it lasts longer than about 15 seconds, check the network and the server.
The app is not configured yet.No data source has been chosen.Press Settings and choose the program — Settings.
No connection to the data source / Ask the store staff for help.The app could not connect to the program at start-up or after the settings were saved. The message stays until a connection succeeds.Run the connection test and fix the settings as the message suggests. Every following scan tries to connect again.
Product not foundThe connection works, but the program has no product with this code.Check that the code is assigned to a product and that both search switches are on. With Subiekt nexo and WAPRO Mag the product must have a price in the chosen price list.
Data download error (in red)The product query failed, also after reconnecting.Check the network and the server. If the connection test passes but every scan gives this error, the login lacks permission to one of the tables or (with REST API) the API returns an error.

Connection test messages (SQL Server programs)​

MessageCause and fix
SQL Server rejected the login of user …Wrong login or password, or SQL Server authentication is disabled on the server. Check the details and the authentication mode (mixed).
The server has no database … or the user has no access to it.A typo in the database name, or the login has no user in this database (CREATE USER … FOR LOGIN …).
Connected to the server, but … is not a … database.The database entered is not this program's company database (e.g. the Optima configuration database). Enter the company database.
Server … has no instance …Wrong instance name after the backslash. Check it or enter the port, e.g. 192.168.1.10:1433.
Could not connect to instance … on server …The app did not get the instance port. Start the SQL Server Browser service and open UDP 1434, or enter the instance port in the address.
Computer … cannot be found on the network.The price checker cannot resolve the computer name. Enter the server's IP address.
Server … does not respond on port …Wrong address, server switched off, a firewall, or the TCP/IP protocol is disabled in SQL Server.
Server … refuses connections on port …The server is up, but SQL Server is not listening on this port. Check the instance port and the firewall.
The server closed the connection. If the server requires encryption, check “Encrypt connection (SSL)”.The server forces encryption — check the SSL box.
There is no price list “…”. Available: … / Enter the price list name. Available: …Subiekt nexo, WAPRO Mag: copy one of the listed names.
There is no price level “…”. Available: … / Enter the price level name. Available: …Subiekt GT, Navireo: copy one of the listed names or enter the level number.
Could not connect to the data source. The cause is in the technical details below.Another error. Expand Technical details ▸ — e.g. “The SELECT permission was denied” means a missing GRANT SELECT on a table. Pass the details on to the service team.

The Check file button messages (Small Business) are described on the Small Business page.

Messages when saving the settings​

MessageFix
Invalid price pattern. Use e.g. %.2f złThe Price format field must contain %.2f (or %.0f, %.1f) — examples.
Enter the settings access code.The Settings access code field cannot be empty.

Common situations​

  • Nothing happens after switching the price checker on — the app does not start by itself; start Price checker from the app list or set up automatic start with SureLock.
  • A scan has no effect — scans are ignored during the first connection (Loading); wait for Scan the code. If this does not help, the scanner may not be sending Enter after the code — contact HDWR service.
  • The setting code does not open the settings — the access code has been changed. Use the new code; if nobody knows it, clear the app data in the Android settings (this deletes all settings).
  • The price does not match the till — check that the settings use the right price list or price level and the right net/gross choice. With Small Business the change is visible only after the next file reload.
  • No connection to the data source in the morning, then it works — the price checker came up before the server or the WiFi. Scanning any code is enough — the app will try to connect again.

Troubleshooting — FAQ

What does the message No connection to the data source mean?
The app could not connect to the program with the prices at start-up or after the settings were saved. Open the settings, press Connection test on the Source tab and fix what the message points to. Once the cause is fixed, scanning any code is enough – the app reconnects.
Why does the price checker show Product not found although the product is in the program?
The most common causes: the code on the package is an additional barcode in the program, while the program only searches the primary one (Subiekt GT, WAPRO Mag); the Search by EAN code switch is off; or the product is not in the chosen price list (Subiekt nexo, WAPRO Mag).
The connection test passes, but every scan gives Data download error. Why?
Usually the SQL login lacks SELECT permission on one of the tables the app uses – the list of tables is on your program's page. With REST API the cause is an API response other than 2xx or a response without the name or price field.
What should I do when the test shows Computer cannot be found on the network?
Enter the server's IP address in the Address field instead of the computer name, e.g. 192.168.1.10:1433. Android does not always resolve computer names from a Windows network.
What should I send to HDWR service when reporting a problem?
The program name and version, the app version from the General tab, the connection test message and the expanded Technical details. Do not send the database password.